For laying marble what is better of 'lal rorhi' and stone gatki with mixer. lal

For laying marble what is better of 'lal rorhi' and stone gatki with mixer. lal rorhi seems to be flexible for fixing things exactly to floor level like ac drains or underfloor electric conduits etc. And for upper floors lighter than stone gatki. pros/cons?.
106
views
3
answers

I want to build bedroom loft of 2 feet extend from wall. The side walls are 11'

I want to build bedroom loft of 2 feet extend from wall. The side walls are 11'2" apart. Left wall is 9" external common wall and right wall is 4.5" partition wall. so slab would be 11'2" x 2'What should be thickness of rcc slab?How much should 4.5 wall be chiselled and how much 9" left wall and how much the 9" wall where this slab would stuck like a cantilever. What would be optimum considering .
253
views
4
answers

What should be lintel design above door frame of 2'6" wide, 4.5" section and 2.5

What should be lintel design above door frame of 2'6" wide, 4.5" section and 2.5 inch thick hollow galvanised steel of 1.5mm thickness? Wall thickness is 4.5 inch brick? This will be 4 feet brickwork above lintel..
885
views
1
answers

Independent Beam vs integrated beam in roof slab

I will be building house. contractor showed me other constructions where beam is integrated in roof slab itself. say for slab of 4.5 inch , remaining 4.5 inch of 9inch beam shows on upper side. I guess this is possible to have to lower side also?Question : What is advantage / disadvantage of these integrated beams?.
610
views
1
answers

How should be footing net for column adjacent to existing wall

How should be footing net for column adjacent to existing wall?My coulmn will go 36' above plinth and 7' below plinth level. Plinth level is 2' above front road and 4' above adjacent ground level.I am asking as 3'x3' net is not possible with column at centre. thanks- Surinder.
 Surinder Singh's Videos (0) 
No video(s) found..!
 
 Fresh at Surinder Singh's profileSee All    
  23 February, 2019
No content(s) available..!

 Surinder Singh's ProjectsSee All
 Contact Information
Address: 
City: 
Zip: 
Country: 
Website: 
 Education and Work Experience See All
 Education Info
No education(s) found..!
 Experience Info
 No experience(s) found..!
Copyright 2007- GharExpert.com All rights reserved.  

 
 |  Advertize with us  |  About us  |  Contact us  |  RSS  |  Blog  |  Terms of service  |  Style made simple  |  Decorating slide show  |  Tips  |  Give your feedback  |