Question details
 
What are the reasons for dampness in the buliding?

Price : Rs.0
Paid : Rs.0
Balance : Rs.0
Question category : Dampness
On : 05/04/2008
Views : 1781
Status : Closed
Files attached : No files
Expert(s) chosen:  No experts
   
 
Status history
Answered by Ruchika on Mon Nov 19, 2007 5:07 PM
 

The reasons of dampness in the building are following.

 

  • Bitumen /Tar- felt coat on RCC slab is not proper or is done leaving some area and joints.
  • Cement concrete ‘gola’ with junction of wall and slab is not constructed or defective or broken. 
  • Rain water pipe joints are defective and there is leakage even on smaller blockage.
  • Rain water pipe mouth have crack in it.
  • Sometimes rainy water pipe inlet is higher than ‘Khurra level’.
  • Some time there is a gap between the mouth of rainy water pipe and roofing.
  • The tracing at roof does not have required slope.
  • Earth place on RCC slab for making slope is not properly rammed. 
  • Some depression exists on the surface of tile tracing where the water is stagnated.
  • Broken tiles are used.
  • The joints of “Chhaja /Cantilever” are not properly finished with the walls.
  • Drip course not made or broken.
  • Proper sill of windows and ventilator is not constructed.
  • The masonry joints of the walls are week and are not covered with cement plaster or cement pointing.
  • Proper ‘Damp Proof Course’ at the floor level is not made on the walls.
  • Rainy water discharge is not through proper shoe in the pipe.
  • Plinth protection is not made around the building.
  • The joints of Water supply and sewer line have some leakage.
  • Under water tank at roof, no water proofing is done.
  • Gap between the tile tracing and support of water tank is left.
  • Joints of tile tracing are not filled properly with mortar.
  • Cement pointing is defective at the top of tile tracing.
  • There is leakage from the water tank.
  • Proper ball cock is not fitted in the water tank.
  • Over flow pipe is not fitted in the water tank.

 

Files attached : No files

Copyright 2007- GharExpert.com All rights reserved.  

 
 |  Advertize with us  |  About us  |  Contact us  |  RSS  |  Blog  |  Terms of service  |  Style made simple  |  Decorating slide show  |  Tips  |  Give your feedback  |